CATALOGUE LH5154
DIESEL OPACITY MODULE
LH5154 The LH5154 is a opacity measurement module which measures the smoke opacity and must be connected to a terminal to display the results (with a standard RS232). This device could be the display module of the LH5054, a gas analyser (LH5172/GAS or LH5059), any personal computer, or any other device supporting a standard RS232 protocol.
LH5154 Module Characterístics
Partial flux measuring technique. Compatible with the free acceleration tests (among other, those described in the European Directive 92/55) - Operating life over 20,000 hours - Warming up time: 3-5 minutes - Ergonomic design: small size and low weight - Easy cleaning of lens.
Complies with the standards:
Electrical: IEC 801-1 /-2 /-3 /-4, EN 50 081-1 /-2, EN 50 082-1 /-2
Specific: Spain UNE82503, Germany PTB EO 18-09, France NF R 10-025


Power supply: 230Vac, 50/60 Hz. Dimensions mm (feet) 235 (0.77) large x 90 (0.30)deep x 380 (1.25) high (without the supports). Weight: 8 kg (36 lbs.)
Metrological characteristics: Precision : ±2% Resolution 0,1% ó 0,01 m-1 Range 0-16,06 m-1 or 0-99.9% Operating temperature +5..+40ºC (40..105ºF) Relative humidity 0..95%

PRECISION ±2%
RESOLUTION 0,1% / 0,01 m-1
RANGE 0-16,06 m-1 / 0-99,9%
TEMPERATURE 5..40ºC
HUMIDITY 9..95%